Upstate Medical Physics, Inc.
Upstate Medical Physics, Inc.
 

“Top quality service is what comes to mind when speaking about UMP. Going that extra mile to make sure that our needs are met and that their work is impeccable. Each physicist presents himself with professionalism and confidence. From their entrance to exit the experience far surpasses all others. Working with UMP is enjoyable and worry free and the friendship we have developed over the years is one that we are very proud of.”

R. Barletta,
Cortland Regional Medical Center

 
View Testimonials

Services

Acceptance Testing

New York and many other states require that new imaging equipment be tested before first use on patients. This is also recommended in the ACR Standard of Practice and in their Accreditation programs. UMP has extensive experience providing acceptance testing for new imaging equipment, including radiographic and fluoroscopic X-ray, C-arms, CT units, Nuclear Medicine cameras, PET and PET/CT units, MR units, mammography equipment, CR readers and PACS workstations.

Through our thorough testing and measurements, we have been able to help clients verify that their equipment meets manufacturer specifications and regulatory requirements, as well as identify any problem areas that will need to be addressed to ensure that their substantial investment in new equipment is maximized.

Most of our clients have felt that the cost of acceptance testing by an independent, experienced physics group is extremely worthwhile when compared with the overall cost of the new imaging equipment. They are especially grateful on those occasions when we have discovered significant problems that require correction before patient imaging begins (and before full payment is made).

We believe acceptance testing by an independent physics group such as ours is akin to having your car or house inspected by an independent party prior to purchase. It’s a relatively small investment for a fairly complex piece of imaging equipment. In past acceptance testing for other clients, we have identified issues that had required corrective action by the vendor. We have built excellent collaborative relationships with local service engineers, because we work together to ensure your imaging equipment works at its optimum performance.

Q&A

Are there any requirements for acceptance testing?

Some states, like New York, require acceptance testing of all medical diagnostic equipment before first use on patients. “Diagnostic equipment,” includes Nuclear Imaging Systems (SPECT and PET), CR readers and plates, and PACS workstation displays. This clarifies the common misconception that acceptance testing is only required for x-ray producing equipment.

Click Here for the link to the NYS regulation for Acceptance Testing.

Can acceptance testing be done by the manufacturer?

In New York State, the Medical Physics Licensure Law (Article 166 of the Education Law) specifies that acceptance testing is one of the practices that may only be performed by a licensed medical physicist. In section 8702, under the “definition of the practice of medical physics” that “Acceptance testing” is listed within the scope of practice.

Note that the education law is not typically enforced by NYSDOH inspectors. The Medical Physics licensure law does not restrict unlicensed persons from acquiring data, but rather requires oversight from a licensed medical physicist.

The bottom line is that, in New York State, Part 16 (Health Law) says that all diagnostic imaging equipment must be acceptance tested, and Article 166 (Education Law) specifies that acceptance testing must be performed by a licensed medical physicist.

<- Back to Services / Modalities & Equipment Chart


ACR and IAC Accreditation Assistance
Each year, more imaging departments at hospitals and private centers are seeking to join others who have achieved accreditation by the American College of Radiology and/or IAC (ICANL, ICACTL, etc.) in various imaging modalities. UMP has developed substantial expertise assisting clients through the accreditation process by providing physics support for mammography, CT, MR, and Nuclear Medicine programs.

<- Back to Services / Modalities & Equipment Chart


Shielding Design
Protection of employees, patients, and the general public from primary, scattered, and leakage radiation is the primary goal of shielding design. UMP has provided shielding recommendations for hundreds of diagnostic installations, including radiographic, fluoroscopic, CT, nuclear medicine, PET, and PET-CT imaging equipment. We use the latest methodologies described in NCRP 147, to provide you with accurate, concise reports. We also have substantial experience with providing the paperwork required for Certificate of Need (CON) projects.

We strive to balance our main objectives of safety and regulatory compliance with cost and prudent design on every job. UMP can work directly with the architectural or construction firm, as needed and can provide expert advice on layout and other design features. We also offer quick turn around times for rush projects (3-day is available for single room projects).

Shielding design has really changed in the past 30 years. It has always been prudent to perform a shielding design for a new or renovated facility. With the latest changes in CT technology, we find that most existing CT scanner rooms need additional shielding to safely accommodate the new multi-detector CT scanners and their greatly increased mAs workloads. Because many facilities cannot verify the amount of existing lead in x-ray rooms, we are able to make an on-site determination of the existing lead, helping to maintain safety and minimize unnecessary expense.

<- Back to Services / Modalities & Equipment Chart


Consulting – Regulatory, Quality Control, Technology
Medical imaging is becoming anything but simpler. Not only is the technology becoming increasingly complex, there are a multitude of regulatory requirements and quality control tests that change continually. We pride ourselves in providing prompt, professional advice on regulatory, quality, and technology issues for all our clients. Your answer is just a short phone call or email away. When necessary, UMP consults with a network of colleagues in the regulatory, manufacturing, and physics communities.

<- Back to Services / Modalities & Equipment Chart


Procedures & Manuals
Most regulators and accreditation organizations (such as JCAHO) require imaging departments to have current written procedures that document routine department activities. Written procedures also help to ensure all affected employees are aware of expected practices. UMP has written concise, straight-forward procedures and manuals for numerous clients, and can tailor documents to fit most any format.

<- Back to Services / Modalities & Equipment Chart


Fetal Dose Estimates
When a pregnant patient is inadvertently exposed to diagnostic medical radiation, it is important to know the dose to the fetus. Based on imaging parameters provided by the client, UMP can provide an estimate of the fetal dose from diagnostic X-ray, CT, PET, or nuclear medicine procedures, and compare the dose to acceptable guidelines.

Click Here for an X-ray Fetal Dose Estimation worksheet.

Click Here for a CT Fetal Dose Estimation worksheet.

<- Back to Services / Modalities & Equipment Chart


Radiation Safety Training
Radiation safety training is integral for technologists, physicians, nurses, and others who may be exposed to radiation in the course of their work. Most regulators require initial radiation safety training for occupationally exposed workers, and an annual or periodic refresher.

UMP has provided hundreds of radiation safety presentations to all levels of staff. Our experienced instructors, who themselves regularly attend professional meetings and seminars, ensure that the most current information is provided, and can tailor courses to fit the needs of your facility. Contact us for more information.

<- Back to Services / Modalities & Equipment Chart


Personnel Dosimetry Analysis and ALARA Program
Whether film badges, TLD or OSL badges are used, management of personal monitoring systems and records are very important from a safety, regulatory and legal standpoint. UMP has helped clients with their dosimetry program in several ways:

  • Review of dosimetry reports and generation of ALARA reports (Investigational Levels I and II)
  • Investigations of high doses with follow-up regulatory support, if warranted
  • Determination of which employees require a dosimeter by reviewing past histories and potential for exposures
  • Reviewing the latest available client records online via the vendors website (e.g., Landauer, Global Dosimetry)

<- Back to Services / Modalities & Equipment Chart


Annual/Periodic Testing

Mammography
Since the ACR initiated its Mammography Accreditation Program in 1987, and subsequently President George H.W. Bush signed the Mammography Quality Standards Act into law in 1992, UMP has developed a passion and an expertise for providing medical physics services to mammography facilities. We have more than 20 years of experience assessing mammography systems, including screen-film, DR and CR digital mammography, of nearly every manufacturer. We survey well over 100 mammography facilities each year – from large university and private practice centers to small hospitals and multi-specialty clinics. To meet MQSA standards, UMP incorporates the following tests: collimation assessment, system resolution, AEC assessment, screen speed uniformity. Artifact evaluation, image quality evaluation, kVp, HVL, breast entrance exposure, average glandular dose, radiation output rates. compression evaluation, viewbox luminance, and QC program review.

<- Back to Services / Modalities & Equipment Chart


Upstate Medical Physics, Inc. • 7867 Parish Road • Victor, NY • 14564 • 585-924-0350 • Fax 585-924-5765